- Bromine
- Chlorine dioxide
- Chromium VI
- Iron
- Total chlorine
- Free chlorine
- Polymer
- Silicate
- Sulfite
- Ortho Phosphate
Filter products
500 ml-bottles of original Reagent set PO4 2100 A + B can be used immediately in the Testomat 2000®® PO4 without cumbersome filling and refilling. Measuring range: Phosphate PO4: 0.0 - 10.0 mg/l
Testomat Antox solution 2x100ml bottles for the targeted elimination of interference from oxidising agents in Testomat 2000 Antox measuring devices. Testomat Antox solution – for stable measurements despite oxidising agents Reducing agent solution to prevent incorrect analyses of water samples The Testomat Antox solution is supplied in 2x100ml bottles and is a special additive solution for use in Testomat 2000 Antox measuring devices. Oxidising agents such as chlorine, chlorine dioxide or ozone can influence the indicators in water analysis systems and lead to measurement errors. By adding a suitable reducing agent before the analysis, such interference is specifically reduced so that the measurement process can be continued correctly. Why is Antox solution important for oxidising substances? Concentrations of oxidising agents such as chlorine, chlorine dioxide or ozone that exceed the limits permitted by the TVO (Drinking Water Ordinance) have a detrimental effect on the dye contained in the Testomat 2000® reagents. An accurate determination of water hardness can then no longer be guaranteed and the Testomat® device displays the error message ‘Measurement error analysis’ (MST analysis). In order to perform the measurement correctly, a reducing agent must be added. The Testomat 2000® Antox measuring device is a special version of the Testomat 2000® with an additional pump for dosing a reducing agent. Adding a reducing agent to the filled measuring chamber prevents an oxidising agent error before each analysis. Further analysis of the water hardness is then continued according to the standard procedure. Specially developed for Testomat 2000 Antox devices The Antox solution is designed for use with the Testomat 2000 Antox measuring device, which has an additional pump for dosing the reducing agent. Before each hardness measurement, the solution can be dosed automatically or manually to minimise measurement errors caused by oxidising agents. Order the Testomat® Antox solution 2 x 100 ml conveniently online now! Take advantage of a 3% price reduction on all Heyl products in our online shop and enjoy fast shipping and expert advice. Do you have any questions about this product? Our team will be happy to advise you by telephone.
Original Testomat 2000® Bromine reagent set The original 500 ml bottles can be used immediately for Testomat 2000® Br. Monitoring the content of bromine (Br2) in the range of 0 - 5.6 mg/l (ppm).
The Testomat 2000 Chlor Reagent Set F consists of two bottles of Reagent CL 2250 A (2 x 500 ml) and one bottle of Reagent CL 2250 B (1 x 400 ml) and has been developed for the precise determination of free chlorine in water samples. Coordinated reagent set for the determination of free chlorine The Testomat 2000 Chlor Reagent Set F is part of a coordinated system and combines the components CL 2250 A and CL 2250 B for the reliable determination of the free chlorine concentration. Together, the reagents cover the intended measuring range (0 – 2.5 mg/l) and ensure stable results. The dosing volumes are selected to guarantee uniform consumption over the operating period. The guaranteed minimum shelf life is 4 months. Suitable for: Automated measurement of free chlorine in water samples Use in Testomat 2000 CLF analysers Continuous monitoring of water quality Not suitable for: Applications in non-compatible measuring devices Manual test procedures without Testomat devices Use as a disinfectant or water additive Areas of application: Monitoring of chlorination systems for drinking water/swimming pool water Protection of reverse osmosis membranes Monitoring of chlorine-containing biocides and conditioning agents Efficient operation through well-designed bottle volumes The reagent set consists of 2 x 500 ml A reagent and 1 x 400 ml B reagent, with the different filling volumes designed for uniform consumption in the Testomat devices. This ensures efficient use and reduces the need for frequent refilling. Use only original Heyl reagents, which are specially matched to the requirements of Heyl measuring devices and ensure flawless measurement results. Order the Testomat 2000® Chlor Reagent Set F quickly and conveniently online now. Benefit in our online shop from a price advantage of 3% on all Heyl products as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
The Testomat 2000 Chlor Reagent Set T is used for the reliable determination of total chlorine in water samples. The set contains reagents A (2 x 500 ml), B (1 x 400 ml) and C (1 x 200 ml) and can be used in the Testomat 2000® THCL®, Testomat 2000® CLT and Testomat 2000® CLT self clean. It enables automatic monitoring within a measuring range of 0 to 2.5 mg/l. Reliable control of total chlorine levels in water systems With this reagent set, the total chlorine value can be monitored easily and safely. The included components work together to deliver accurate measurement results and to detect changes in the water at an early stage. The reagents have a guaranteed minimum shelf life of 4 months. Suitable for: Automatic measurement of total chlorine in technical systems Monitoring of water quality in cooling and process systems Applications with a regular requirement for chlorine checks Not suitable for: Manual tests without analysers Direct addition to water for treatment or disinfection Use in non-compatible devices Areas of application of the reagents in combination with a Testomat device from Heyl: Monitoring of chlorine gas systems for drinking water/swimming pool water (Testomat 2000 CLT) Protection of reverse osmosis membranes (Testomat 2000 CLT) Monitoring of chlorine-containing biocides and conditioning agents (Testomat 2000 CLT) Monitoring of disinfectant dosing in drinking water applications as well as in process water applications (Testomat 2000 CLT self clean) Medical technology (dialysis) (Testomat 2000 CLT self clean) Easy replacement and safe operation The reagent bottles can be inserted directly into the Testomat devices. This simplifies handling and prevents errors during refilling. Measurement operation remains stable without the need for frequent interruptions. The reagent sets are designed for uniform reagent consumption; therefore, the filling volumes of the individual reagent bottles differ. Use only original Heyl reagents, which are specially matched to the requirements of Heyl Testomat measuring devices and ensure flawless measurement results. Order the Testomat 2000® Chlor Reagent Set T quickly and conveniently online now. Benefit in our online shop from a price advantage of 3% on all Heyl products as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
The Testomat 2000 Chlor Reagent Set T 50% has been developed for the automated determination of total chlorine in water samples. The set contains Reagent A (1 x 500 ml), Reagent B (1 x 200 ml) and Reagent C (1 x 100 ml) and is specifically designed for the Testomat 2000® CLT, Testomat 2000® CLT Self Clean, and Testomat 2000® THCL® devices from Heyl. It delivers reliable results and is suitable for regular measurements during ongoing operation. Simple monitoring of total chlorine levels With the Reagent Set T 50%, you can continuously monitor the total chlorine level in technical water systems. Reagents A, B, and C are coordinated and work together to ensure that the Testomat devices provide clear, stable measurement results. This allows changes in water quality to be detected early and acted upon in a timely manner. The guaranteed minimum shelf life of the reagents is 4 months. Suitable for: Automatic total chlorine measurements in water systems Control measurements in cooling and process circuits Regular monitoring without manual intervention Not suitable for: Manual tests without analysers Use as a chemical additive for water treatment Operation in non-compatible measuring systems Areas of application of the reagents in combination with a Testomat device from Heyl: Monitoring of chlorine gas systems for drinking/swimming pool water (Testomat 2000 CLT) Protection of reverse osmosis membranes (Testomat 2000 CLT) Monitoring of chlorine-containing biocides and conditioning agents (Testomat 2000 CLT) Monitoring of disinfectant dosing in drinking water as well as in process water applications (Testomat 2000 CLT self clean) Medical technology (dialysis) (Testomat 2000 CLT self clean) Practical packaging for easy replacement The reagent sets are designed for uniform reagent consumption; therefore, the filling volumes of the individual reagent bottles differ. The coordinated consumption allows maintenance intervals to be planned more effectively. The bottles can be inserted directly, eliminating the need for transferring contents. Use only original Heyl reagents, which are specifically matched to the requirements of Heyl Testomat measuring devices and ensure flawless measurement results. Order the Testomat 2000® Chlor Reagent Set T 50% quickly and conveniently online now. Benefit in our online shop from a 3% discount on all Heyl products, as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
The 500 ml-bottles of original Testomat 2000® Reagenz CIO2 A/B bottles can be used immediately in the Testomat 2000®® CIO2 without cumbersome filling and refilling. Measuring range: chlorine dioxide (ClO2): 0.00 - 4.70 mg/l
Testomat 2000 Reagent CL 2250 C in the 500 ml bottle is a reagent for monitoring total chlorine. The reagent is part of a coordinated analytical procedure and is used together with reagents CL 2250 A and CL 2250 B to ensure precise measurements within the defined measurement range. Precise analytical reagent for determining total chlorine The Testomat 2000 Reagent CL 2250 C has been specifically developed for the automated determination of total chlorine in water samples. It enables reliable and continuous monitoring of water quality. The coordinated chemical composition ensures stable measurement conditions and reproducible results, thus providing secure process control. The reagent covers a total chlorine measurement range of 0.00 – 0.99 mg/l. The guaranteed minimum shelf life of 7 months allows reliable planning. Suitable for: Automatic total chlorine measurements in industrial water systems Water treatment and process control Cooling water and plant monitoring Use in compatible Testomat 2000 measuring devices Not suitable for: Manual water analyses without Testomat devices Use as a disinfectant or water additive Use in non-compatible analytical devices Reliable use in automated measurement systems The reagent is part of a coordinated analytical procedure and supports continuous monitoring of total chlorine concentration. It helps ensure compliance with limit values, protects systems, and guarantees consistently high water quality. All three reagents CL 2250 A, B, and C are required for total chlorine measurement. Use only original Heyl reagents, which are specifically tailored to the requirements of Heyl measuring devices and thus ensure flawless measurement results. Order the Testomat 2000 Reagent CL 2250 C in the 500 ml bottle easily and conveniently online now. Take advantage of a 3% discount on all Heyl products in our online shop, as well as fast shipping and competent expert advice. Do you have questions about this product? Our team is happy to assist you by phone.
Testomat 2000 Reagent CL 2250 A 500 ml Chlorine Reagent CL 2250 A for Reliable Measurement of Free and Total Chlorine for Safe Water Treatment and System Protection The Testomat 2000 Reagent CL 2250 A, 500 ml bottle, is used for measuring total chlorine and free chlorine in water samples. The measuring range is 0.00–0.99 mg/l (resolution 0.01 mg/l) and 1.0–2.5 mg/l (resolution 0.1 mg/l). The CL 2250 A reagent can be used directly in Testomat 2000 CLF or CLT devices without transferring and is ideal for membrane protection in reverse osmosis systems. Where can the CL 2250 reagent be used to monitor chlorine? It can be used in: Testomat 2000® THCL® Testomat 2000® CLF Testomat 2000® CLT Testomat 2000® CLT self clean Why is measuring free and total chlorine so important? Measuring free and total chlorine is a central part of professional water monitoring. Free chlorine (e.g., hypochlorous acid and hypochlorite) is the disinfecting form and crucial for the microbiological safety of water. Total chlorine also includes combined chlorine (chloramines), which has disinfecting properties but is significantly less effective and can lead to odor and corrosion problems. Monitoring free and total chlorine is essential to ensure water quality, the effectiveness of disinfection, and to detect possible over-concentration in process water. In sensitive applications such as reverse osmosis systems, precise chlorine monitoring is particularly important because free chlorine can damage or destroy membranes. The CL 2250 A reagent supports safe process control, protects system components, and helps reliably maintain standard and limit values. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
The Testomat 2000 Reagent FE 2005 A is used for the reliable determination of dissolved iron in water. Together with Reagent FE 2005 B, it is used in compatible Testomat analysers and provides precise measurements in the range of 0–1.0 mg/l – with a guaranteed minimum shelf life of 7 months. Automatic iron measurement in water The reagent is suitable for the Testomat 2000 FE and helps to regularly monitor the iron content in technical or industrial water systems. The measuring range is 0–1.0 mg/l dissolved iron, allowing even small changes to be detected reliably. It is suitable for system monitoring, water treatment or the monitoring of iron removal systems. The product is not suitable for manual water analyses without the Testomat, as an additive in water or for other measuring devices. Why should I only use original reagents? The reagent bottle fits directly into the analyser, thereby reducing the risk of dosing errors or contamination. Measurement therefore remains reproducible and predictable. This is particularly important for continuous system monitoring. Reagents A and B are matched to the Testomat 2000 FE measuring device. The Testomat 2000® FE process photometer is a robust wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the range of 0 to 1.0 mg/l (ppm) using the colourimetric analysis principle. The analysis is carried out by adding two reagents and, after a reaction time of approx. 7 minutes (pure measurement time without rinsing times), the analysis result is displayed. Areas of application include, for example, the monitoring of iron removal systems or the control of service or drinking water flows. Trouble-free operation of the Testomat 2000® FE device is only guaranteed when using Heyl Testomat 2000® reagents FE 2005 A and FE 2005 B! Therefore, use only original Heyl reagents, which are specially matched to the requirements of the measuring devices and thus ensure flawless measurement results. Order the Testomat 2000® Reagent FE 2005 A in the 500 ml bottle quickly and conveniently online now. Benefit in our online shop from a price advantage of 3% on all Heyl products as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
Content: 0.5 Liter (€629.20 / 1 Liter)
The Testomat 2000 Reagent FE 2005 B is a component of the iron measurement system in the Testomat 2000 FE. Together with Reagent FE 2005 A, it helps to automatically monitor the iron content in water and detect changes at an early stage. Clear results in iron monitoring This reagent is used to reliably determine dissolved iron in water. It supports measurements in the range up to 1.0 mg/l and is suitable for iron monitoring in systems where iron deposits or corrosion are to be avoided. Water quality is thus monitored without the need for constant manual measurements. The reagent has a minimum shelf life of 7 months. Suitable for: Automatic iron measurements in water treatment Monitoring of well water, process water and cooling water Regular monitoring of systems with iron contamination Not suitable for: Manual measurements without a Testomat Use as an additive for water treatment Use in other measuring devices Reagent FE 2005 B is always used together with FE 2005 A. Only both reagents together provide accurate results, as they are matched to the device’s measurement procedure. Why should I only use original reagents? The original bottle can be inserted directly into the Testomat 2000® FE device without transferring. This reduces the risk of errors or contamination. This is particularly helpful for systems that must be continuously monitored. The Testomat 2000® FE process photometer is a robust wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the range of 0 to 1.0 mg/l (ppm) using the colourimetric analysis principle. The analysis is carried out by adding two reagents and, after a reaction time of approx. 7 minutes (pure measurement time without rinsing times), the analysis result is displayed. Areas of application include, for example, the monitoring of iron removal systems or the control of service or drinking water flows. Trouble-free operation of the Testomat 2000® FE device is only guaranteed when using Heyl Testomat 2000® reagents FE 2005 A and FE 2005 B! Therefore, use only original Heyl reagents, which are specially matched to the requirements of the measuring devices and thus ensure flawless measurement results. Order the Testomat 2000® Reagent FE 2005 B in the 500 ml bottle quickly and conveniently online now. Benefit in our online shop from a price advantage of 3% on all Heyl products as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
Content: 0.5 Liter (€683.40 / 1 Liter)
Bulk container - 20 litre canisterTo use the canister, the suction lance (art. no.: 40535) is required.
Bulk container - 5L canisterTo use the canister, the suction lance (art. no.: 40536) is required.
Testomat 2000 Reagent CL 2250 B 500 ml Second reagent for chlorine measurement with the Testomat 2000 Chlorine system Precise chlorine analysis with Testomat 2000 Reagent CL 2250 B The Testomat 2000 Reagent CL 2250 B is specifically designed for reliable determination of free and total chlorine in water. As a second reagent, it complements Reagent A and allows accurate measurement without additional transfer steps. Thanks to its fine resolution, the reagent is ideal for applications requiring precise and continuous chlorine monitoring. Measurement range and advantages of Reagent CL 2250 B The measurement range of the reagent is 0.00–0.99 mg/L with a resolution of 0.01 mg/L, and 1.0–2.5 mg/L with a resolution of 0.1 mg/L. This allows both very low and higher chlorine concentrations to be accurately detected. In combination with Reagent A, CL 2250 B ensures reliable, reproducible, and low-maintenance chlorine determination. Where can the reagent be used? Reagent CL 2250 B is suitable for use in various Testomat 2000 series devices and supports flexible applications in different measurement environments. Compatible Testomat 2000 devices The reagent can be used in the following devices: Testomat 2000® THCL® Testomat 2000® CLF or CLT Testomat 2000® CLT self clean Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Testomat Self Clean cleaning solution in a 500 ml bottle for automatic removal of dirt in the measuring chamber or drain hose in Self Clean measuring devices. Testomat Self Clean cleaning solution 500 ml – order online Cleaning solution for the safe removal of deposits in the measuring chamber and hose Testomat Self Clean cleaning solution has been specially developed for the automatic removal of contamination in the measuring chamber and drain hose of Self Clean measuring devices. The programmable cleaning cycle of the devices ensures that deposits from calcareous water, biofilms or other residues do not accumulate and falsify the measurement results. Automatic cleaning for stable measurement results The cleaning solution has been developed for regular use in automated cleaning cycles. Continuous cleaning keeps optical and hydraulic components free of residues, which supports measurement stability over long operating periods. Developed for Testomat® devices with self-clean function in continuous operation In Testomat measuring devices with integrated Self Clean function, the cleaning solution is automatically dispensed at defined analysis intervals. This makes it particularly suitable for systems with high measurement frequency or contaminated measurement water. The solution reduces manual intervention and unplanned maintenance work. Order the Testomat Self Clean cleaning solution 500 ml conveniently online now! Take advantage of a 3% price reduction on all Heyl products in our online shop and enjoy fast shipping and expert advice. Do you have any questions about this product? Our team will be happy to advise you by telephone.
The Testomat 2000 SO 3 Reagent A is a specially calibrated analytical reagent for the determination of sulphite in water samples. It delivers reliable results without manual measuring. Reliable sulphite analysis in automatic measurement operation The SO 3 Reagent A has been developed to monitor the sulphite content in water safely and continuously. The chemical composition has been specifically tailored to the measurement procedure, ensuring that the readings are stable and traceable. The guaranteed minimum shelf life of 7 months allows for planned analysis schedules. Suitable for: Automatic sulphite measurements in technical water systems Use in the Testomat 2000® SO 3 Regular monitoring of water quality Processes where SO 3 monitoring is important Not suitable for: Manual analysis procedures without an analyser Use as an additive for water treatment Use in non-compatible devices Easy use in the Testomat 2000 SO 3 The 500 ml bottle can be inserted directly into the Testomat 2000 SO 3 analyser without the need for transferring contents. This saves time and ensures smooth operation. The risk of measurement errors due to incorrect filling is reduced. The Testomat 2000® SO 3 device is a robust wet-chemical online monitor for monitoring the sulphite SO32- content in the range of 0 to 50 mg/l using the colourimetric analysis principle. The analysis is performed by adding two reagents, and after a reaction time of approximately 3 minutes (pure measurement time without rinsing), the result is displayed. High measurement accuracy through precise piston dosing pump: Resolution in the range 0–5 mg/l: 0.1 mg/l Resolution in the range 5–10 mg/l: 0.5 mg/l Resolution in the range 10–50 mg/l: 1 mg/l Applications include monitoring of boiler feed water or condensate in steam boiler systems. Flawless operation of the Testomat 2000® SO 3 device is only guaranteed when using Heyl Testomat 2000® SO 3 reagents! Order the Testomat 2000® SO 3 Reagent A in the 500 ml bottle quickly and conveniently online now. Benefit from a 3% discount on all Heyl products in our online shop, as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
The Testomat 2000 SO 3 Reagent B is an analytical reagent for the determination of sulphite in water samples. It ensures precise measurement results. Supplementary Reagent B for sulphite measurement The SO 3 Reagent B is part of a coordinated measurement procedure and complements the analysis of sulphite levels in water. Together with Reagent A (Article No.: 156240), it enables reliable measurement that makes changes in the water circuit visible. Water quality can thus be monitored and deviations can be responded to in good time. The guaranteed minimum shelf life of the reagent is 7 months. Suitable for: Regular monitoring in cooling or process circuits Automatic sulphite measurements with the Testomat 2000® SO 3 Monitoring of technical water systems Not suitable for: Manual measurements without a Testomat Use as a chemical additive in water Operation in non-compatible devices Direct use in the analyser The 500 ml bottle can be inserted directly and easily into the Testomat 2000 SO 3 measuring device from Heyl without the need for complicated transferring. Contamination is avoided and daily operation remains reliable and stable. The Testomat 2000® SO 3 device is a robust wet-chemical online monitoring system for monitoring the sulphite content (SO32-) in the range of 0 to 50 mg/l. The colourimetric analysis method is used. The analysis is carried out by adding two reagents and, after a reaction time of approximately three minutes (pure measurement time without rinsing times), the result is displayed. High measurement accuracy through precise piston dosing pump Resolution in the range 0–5 mg/l: 0.1 mg/l Resolution in the range 5–10 mg/l: 0.5 mg/l Resolution in the range 10–50 mg/l: 1 mg/l Areas of application include, for example, the monitoring of boiler feed water or condensate in steam boiler systems. Flawless operation of the Testomat 2000® SO 3 device is only guaranteed when using Heyl Testomat 2000® SO 3 reagents! Order the Testomat 2000® SO 3 Reagent B in the 500 ml bottle quickly and conveniently online now. Benefit in our online shop from a price advantage of 3% on all Heyl products as well as fast shipping and competent technical support. Do you have any questions about this product? Our team will be happy to assist you by telephone.
Original Testomat Reagent CrVI 2100 A 500 ml bottle – primary reagent solution for Chromium(VI) analysis within the measurable range of 0–5.0 mg/l chromate or 0–1.0 mg/l Chromium(VI). Testomat 2000 Reagent CrVI 2100 A – for the determination of the chromate or Chromium-VI content Original reagent for the Testomat 2000 CrVI measuring instruments The reagent forms the first component in a titration system that photometrically detects chromates or Chromium(VI) in water samples. The measuring range for chromate is 0 to 5.0 mg/l and for Chromium(VI) 0 to 1.0 mg/l, with fine resolution at lower concentration levels and adjusted resolution at higher values. The guaranteed minimum shelf life of 7 months after dispatch allows for long-term use of the reagent. As this reagent is classified as hazardous goods, please be sure to observe the safety data sheet. Applications: Monitoring the chromate content of wastewater in electroplating plants Control of wastewater in the metal processing industry Starter reagent for precise chromate and Chromium-CrVI analyses In a complete measuring cycle, Reagent A is used together with the matching second Reagent B (item no.: 156221) in order to initiate the photometrically based measurements in a targeted manner. The 500 ml bottle is prepared for internal use in Heyl measuring instruments and supports an efficient, repeatable measuring process across numerous samples. The use of third-party reagents may result in significant measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party reagents will void the warranty. Therefore, use only original Heyl reagents, which are specifically matched to the requirements of the measuring instruments and thus ensure flawless measurement results. Purchase the Testomat 2000® Reagent CrVI 2100 A in the 500 ml bottle easily and conveniently online now. Benefit in our online shop from a 3% price advantage on all Heyl products as well as fast shipping and expert technical advice. Do you have any questions about this product? Our team will be happy to assist you by telephone.
Testomat 2000 Reagent CrVI 2100 B – second reagent solution for Chromium(VI) analysis within the measurable range of 0–5.0 mg/l chromate or 0–1.0 mg/l Chromium(VI). Testomat 2000 Reagent CrVI 2100 B – for the determination of the chromate or Chromium-VI content Original reagent for the Testomat 2000 CrVI measuring instruments by Heyl The Testomat 2000 Reagent CrVI 2100 B is the complementary reagent solution for chromate and Chromium VI analysis. It forms part of the photometric measuring method used to determine chromate and Chromium VI concentrations in water samples and is used together with the first reagent A (item no.: 156220). The measuring range includes chromate values up to 5.0 mg/l and Chromium VI values up to 1.0 mg/l, with different resolutions enabling the detection of fine concentration increments. The reagent has a guaranteed minimum shelf life of 4 months after dispatch. Applications: Monitoring the chromate content of wastewater in electroplating plants Control of wastewater in the metal processing industry Why should you only use original reagents for analyses? Two reagents are required in the Testomat 2000 CrVI measuring instrument to carry out a complete analysis of the chromate and CrVI concentrations. Reagent B is specifically designed to represent the second part of the chemical reaction together with Reagent A. The 500 ml bottle of Reagent B can be inserted directly into the Testomat 2000 CrVI without prior decanting or additional steps. The use of third-party reagents may result in significant measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party reagents will void the warranty. Therefore, use only original Heyl reagents, which are specifically matched to the requirements of the measuring instruments and thus ensure flawless measurement results. Order the Testomat 2000® Reagent CrVI 2100 B in the 500 ml bottle easily and conveniently online now. Benefit in our online shop from a 3% price advantage on all Heyl products as well as fast shipping and expert technical advice. Do you have any questions about this product? Our team will be happy to assist you by telephone.
Testomat Chlorine Reagent Kit M (Monochloramine) for the Testomat LAB Monochloramine (NH2CL). (Item no.: 116109)
Original Heyl Testomat 808 SiO₂ Reagent A – Reliable Silicate Measurement First reagent for Testomat 808 SiO₂ measurement The Testomat 808 SiO₂ Reagent A is used to measure the silicate content in water (SiO₂) and is one of the two necessary reagents for silicate measurement with the Testomat 808 Silicate system. SiO₂ Reagent A initiates photometric silicate determination in the Testomat® 808 SiO₂. The measurement range is 0.3–1.2 ppm SiO₂. Reagent A is precisely calibrated to the measurement method of the Testomat 808 Silicate and allows reliable silicate measurement in the range of 0.3 to 1.2 ppm SiO₂. It is ideal for use in RO process water treatment, e.g., in clinical environments. Using the original reagent ensures consistently precise results, which are essential for stable process monitoring. Heyl Original Indicator for Silicate Monitoring in RO Process Water Treatment Using original Heyl reagents ensures not only high measurement accuracy but also proper operation of the Testomat 808 SiO₂ and the retention of warranty and guarantee claims. It is ideal for clinical applications where reliable silicate monitoring is critical. For example, in sterilization of medical instruments, silicate monitoring in RO process water plays a key role in protecting and preserving medical devices. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.
Original Heyl Testomat 808 SiO₂ Reagent B for Silicate Determination Second reagent for silicate measurement with the Testomat 808 Silicate system The Testomat 808 SiO₂ Reagent B is the second required reagent for photometric measurement of silicate content (SiO₂) in water. SiO₂ Reagent B, together with Reagent A, completes the silicate determination using the Testomat® 808 SiO₂. The measurement range is 0.3–1.2 ppm SiO₂, enabling reliable and reproducible silicate analysis. Reagent B is precisely calibrated to the Testomat 808 Silicate measurement method and allows reliable determination of silicate within the 0.3–1.2 ppm SiO₂ range. Advantages of Using Original Reagent B for Testomat 808 SiO₂ by Heyl Using original Heyl reagents is essential for the proper operation of the Testomat 808 SiO₂ measuring device. It significantly contributes to process reliability, long device lifespan, and the retention of warranty and guarantee claims. Häufige Fragen How long does the indicator/reagent last? The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months. How much indicator is used per analysis? When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.). The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis. By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator: Indicators consumption calculator - Heyl Neomeris What sizes are available for the bottles and is there anything to bear in mind? The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. For operation with 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming and the screw cap with hole and insert for the indicator must also be purchased. For Testomat 808 devices, the conversion kit (item no. 37580) must be purchased for the use of 100 ml indicator bottles, and for Testomat 808 SiO2 devices, the insert with screw cap and suction tube (item no. 37645) and the hose connector ø 3.5 mm (item no. 37643) must be purchased. For all other Heylwelt Testomat devices, please use the conversion kit with item no. 40143. Where can I find the safety data sheet? The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads – Safety data sheets. How can the indicator be disposed of? Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations. Can the indicator still be used after the expiry date? The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed. What is the optimum storage temperature for the indicator? Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C. Device warranty / guarantee Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.